The A to Z of Microbial Control, Monitoring, Validation and Troubleshooting of Pharmaceutical Water Systems

5 years ago Posted By : User Ref No: WURUR30519 0
  • Image
  • TypeSeminar
  • Image
  • Location Philadelphia, Pennsylvania, United States
  • Price
  • Date 23-04-2019 - 24-04-2019
The A to Z of Microbial Control, Monitoring, Validation and Troubleshooting of Pharmaceutical Water Systems, Philadelphia, Pennsylvania, United States
Seminar Title
The A to Z of Microbial Control, Monitoring, Validation and Troubleshooting of Pharmaceutical Water Systems
Event Type
Seminar
Seminar Date
23-04-2019 to 24-04-2019
Last Date for Applying
21-04-2019
Location
Philadelphia, Pennsylvania, United States
Organization Name / Organize By
Netzealous LLC DBA - Globalcomplianepanel
Organizing/Related Departments
Healthcare
Organization Type
Organization/Company
SeminarCategory
Both (Technical & Non Technical)
SeminarLevel
All (State/Province/Region, National & International)
Related Industries

Education/Teaching/Training/Development

Accounting/Financial/Banking/Insurance

Manufacturing

Medical/Healthcare/Hospital

Location
Philadelphia, Pennsylvania, United States

Description:

This course is designed to provide a microbiology-focused education about all aspects of water systems and how biofilm manages to thrive there. Prior microbiological education or training, though a plus, is not a requirement because engineers and other non-biologists also need this training if they are involved with any aspect of water systems. The instructor will provide the necessary background needed to understand this very important subject matter. This understanding is essential to the proper design, validation, operation, monitoring, maintenance, troubleshooting, and excursion investigations of a high purity water system. Without this understanding, water system control consists of a set of rules that often don't work and can cause very costly system downtime or even product recalls, and leaves the user without a clue as to what went wrong or how to effectively fix it so it doesn't recur.

Why you Should attend:

Much fear and hype exists with pharmaceutical biofilms, especially those in water systems. Long term biofilm control cannot be achieved from a blind set of hand-me-down rules for design and operation. One must truly understand biofilm to be able to control it. And because every water system is unique, understanding how biofilm is trying to grow in your system, which could be different than any other system. This course will give you that understanding that is translatable to any system, so that uneventful microbial control is possible. Without this understanding you will quickly find that blind rules for operation (and design) eventually fail to work, and the consequences of failure will far exceed the educational costs that could have prevented it.

 

Who Will Benefit:

This 2-day course is particularly relevant to managers, supervisors, and operatives taking on new responsibilities related to water, but also for experienced water personnel to learn the "true" whys behind what they do and perhaps better ways of doing things. Specific positions that would benefit are:

  • Microbiology Laboratory supervisors and analysts responsible for water sampling and testing
  • Quality Assurance personnel responsible for water system deviation management and change control
  • Regulatory and Compliance professionals responsible for FDA interactions
  • Process and Utility Engineers responsible for water system maintenance, repairs, troubleshooting, and excursion mitigation
  • Facility Engineers responsible for water system design or renovation

Agenda:

Day 1 Schedule

Lecture 1:

What Makes Water Systems Have Microbial Quality Problems

  • Understand biofilm basics and how it develops
  • Understand the impact of biofilm on the commonly used purification unit operations
  • Understand how various commonly used microbial control strategies work (or don't work) to control biofilm development
  • Understand the how, where, and why of microbial monitoring, action levels, etc.
  • Debunk a few water system myths
  • Get answers to your own water system questions

Lecture 2:

Successful Sanitization Approaches for Trouble-Free Water Quality

  • Material and construction limitations
  • Continuous vs intermittent sanitization
  • The importance of biofilm removal
  • How sanitants work (or don't work)
  • When to sanitize
  • Troubleshooting sanitization problems

Lecture 3:

Water System Validation by Logic Instead of Tradition

  • Why validate a water system?
  • Basic ground rules for water systems before you validate them
  • Micro Test Method "validation"
  • Minimum validation expectations
  • How to figure out what you should validate
  • What happens after the honeymoon is over
  • Is validation ever really over?
  • Special considerations for lab water systems
  • Are packaged waters a viable option?

Lecture 4:

Implementing Changes to a Validated System

  • Purpose of a Change Control program - a help, not a hindrance
  • When is a change major vs minor, requiring full vs limited re-qualification?
  • What about water use during re-qualifications?
  • FDA validation expectations
  • Reliance on logic and common sense and the disservice of precedent and paradigms
  • Additional useful tips

Lecture 5:

Reducing Water Microbial Excursions & Improving Investigations

  • What are excursions?
  • Water system dilemma: process control or quality control (utility or raw material), or both
  • Intended roles of Alert/Action Levels and Specifications
  • Investigation, necessary and often fruitless
  • Excursion responses and impact
  • Criticality of valves, hoses, & outlet flushing
  • Diagnosing the source of the problem
  • Minimizing unnecessary excursion responses through best practices

Day 2 Schedule

Lecture 6:

Understanding and Controlling Endotoxin

  • Where does endotoxin come from?
  • What are the properties of endotoxin?
  • How do you get rid of it?
  • How do you detect it?
  • What assay controls are used?
  • What are the endotoxin specs for water?
  • How do you control it?

Lecture 7:

Harmonizing vs Optimizing Water Microbial Testing for System Quality Control

  • Water harmonization that has occurred
  • Water Micro TM "Dis-Harmonization"
  • A little about Biofilm
  • Biofilm diversity in water systems
  • Micro TM options and evaluation protocol
  • The good and bad of Micro harmonization
  • Where RMMs can fit in
  • Parting wisdom

Lecture 8:

Microbial Enumeration Issues with High Purity Water Systems

  • Microbial Enumeration Issues with High Purity Water Systems
  • Biofilm enumeration issues (planktonic vs surface)
  • Traditional cultivative approach issues
  • Validation of your test method
  • Alternative TM choices (advantages/disadvantages)
  • Significance of water isolates
  • Sampling issues
  • Establishing Alert/Action Levels and Water Specs and defending them to FDA

Lecture 9:

Water System Investigation "How-To's" and Example Case Studies

  • Gathering and assessing existing data and symptoms
  • Considering user opinions
  • Investigation approach elements
  • Recognizing red herrings/false positives
  • Recognizing possible root causes
  • Water system contamination case studies
  • Parting kernels of water system wisdom

Lecture 10:

What USP Does and Doesn't Say about PW, WFI, Pure Steam and Micro Issues

  • PW, WFI, Pure Steam micro specifications?
  • <1231> Starting water issues
  • <1231> Misunderstood issues clarified
  • <1231> Microbiological test issues clarified
  • <1231> Suggested micro test method
  • <1231> Micro Specifications
  • <1231> Alert and Action Levels and max's
  • Recent/Upcoming USP water changes
  • Discrepancies between pharmacopeia's

Speaker:

Dr Teri C. Soli

Principal Consultant, Soli Pharma Solutions

T.C. Soli is a Ph.D. Microbiologist and President of Soli Pharma Solutions, Inc. offering troubleshooting and training expertise covering water systems, sterilization, sterile and non-sterile manufacturing, microbiological laboratories, and microbial and beta-lactam contamination control. He has 38 years of pharmaceutical experience as a consultant and with operating companies including DSM Pharmaceuticals, Glaxo Wellcome, Burroughs Wellcome, and Pfizer.

His career-long water systems and contamination troubleshooting experience, coupled with water-related USP, ISPE, PhRMA, and PDA committee involvements, afford him practical knowledge about contamination control; cleaning, sterilization and process validation; and all aspects of high purity water systems.

Location:  Philadelphia, PA Date: April 23rd & 24th, 2019 and Time: 9:00 AM to 6:00 PM

Venue: DoubleTree by Hilton Philadelphia Airport, 4509 Island Avenue, Philadelphia, PA 19153

 

Price:

1 ATTENDEE $2,000, Register for 1 attendee

5 ATTENDEES $10,000, Register for 5 attendees

10 ATTENDEES $20,000, Register for 10 attendees

Until March 20, Early Bird Price: $2,000.00, From March 21 to April 21, Regular Price: $2,200.00

 

Sponsorship Program benefits for seminar

For More Information- https://www.globalcompliancepanel.com/control/sponsorship

 

Contact us today!

NetZealous LLC DBA GlobalCompliancePanel

[email protected]

Toll free: +1-800-447-9407

Phone: +1-510-584-9661

Website: http://www.globalcompliancepanel.com

 

Registration Link -  https://www.globalcompliancepanel.com/seminar/a-to-z-microbial-control-monitoring-validation-901945SEMINAR?seo

Follow us on LinkedIn: https://www.linkedin.com/company/globalcompliancepanel/

Like us our Facebook page: https://www.facebook.com/TrainingsAtGlobalCompliancePanel/

Follow us on Twitter: https://twitter.com/GCPanel

Registration Fees
Available
Registration Fees Details
1 ATTENDEE $2,000, Register for 1 attendee 5 ATTENDEES $10,000, Register for 5 attendees 10 ATTENDEES $20,000, Register for 10 attendees Until March 20, Early Bird Price: $2,000.00, From March 21 to April 21, Regular Price: $2,200.00
Registration Ways
Email
Phone
Website
Address/Venue
  DoubleTree by Hilton Philadelphia Airport, 4509 Island Avenue, Philadelphia, PA 19153  Pin/Zip Code : 19153
Official Email ID
Contact
Event Manager

DoubleTree by Hilton Philadelphia Airport, 4509 Island Avenue, Philadelphia, PA 19153

[email protected]

     18004479407